Industrial Tri-Proof Tubular Lights for Harsh Environments
Reliable tubular lighting systems for washdown areas, industrial facilities, transport infrastructure, warehouses, and hygiene-critical applications.
Find the Right Industrial Tubular Light
Select the right tubular-light platform by application, protection level, housing material and installation requirement.

Ø45 mm Slim Tubular Light
Best for: Narrow service corridors, machinery, and space-limited installations.

Ø70 mm Industrial Tubular Light
Best for: Warehouses, factories, logistics centers, and general industrial areas.

Ø100 mm High-Output Tubular Light
Best for: Parking garages, tunnels, transport hubs, and high-ceiling spaces.

Ø75 mm Glass Tubular Light
Best for: Food processing, washdown zones, chemical plants, and hygiene areas.

Custom Signage & Wayfinding Tubular Light
Best for: Safety marking, wayfinding, warning messages and visual guidance in industrial facilities.
Need Help Selecting the Right Model?
Share your application, cleaning method, and technical requirements. We will recommend a suitable model and provide specifications and a quotation.
See the Tubular
Lighting Series
Explore MANI industrial LED tubular luminaires and see how their compact, sealed construction supports reliable lighting in demanding industrial, commercial and agricultural environments.
Compare Industrial Tubular Light Platforms
Compare the main MANI industrial tubular-light platforms by diameter, material, protection level, output range, and available configurations. Refer to each product page for model-specific drawings, photometric files, and documentation.
| Specification | Ø45 mm Slim | Ø70 mm Standard | Ø100 mm High Output | Ø75 mm Borosilicate Glass |
|---|---|---|---|---|
| Best For | Narrow corridors, machinery areas, technical rooms, and space-limited installations | Warehouses, workshops, factories, and logistics centres | Parking garages, tunnels, transport infrastructure, and higher-output industrial areas | Food processing, washdown areas, car washes, and hygiene-critical environments |
| Product Models |
MTB-456010 / MTB-456015 MTB-459015 / MTB-459020 MTB-451230 / MTB-451236 MTB-451540 / MTB-451545 |
MTB-706020 / MTB-709030 MTB-701240 / MTB-701550 |
MTB-60030 / MTB-90036 MTB-120045 / MTB-120055 / MTB-120065 MTB-150065 / MTB-150075 |
MTB-756020 / MTB-759030 MTB-751240 / MTB-751550 |
| Dimensions | L600 / L900 / L1200 / L1500 × Ø45 mm | L600 / L900 / L1200 / L1500 × Ø70 mm | L600 / L900 / L1200 / L1500 × Ø100 mm | L600 / L900 / L1200 / L1500 × Ø75 mm |
| Power Range | 10 W–60 W | 20 W–70 W | 30 W–75 W | 20 W–70 W |
| Luminous Flux Range | 1200 lm–5400 lm | 2400 lm–6000 lm | 3600 lm–9000 lm | 2600 lm–6500 lm |
| System Efficacy | 130 lm/W | 130 lm/W | 130 lm/W | 130 lm/W |
| AC Input | AC 220–240 V / 100–277 V, 50–60 Hz | AC 220–240 V / 100–277 V, 50–60 Hz | AC 220–240 V / 100–277 V, 50–60 Hz | AC 220–240 V / 100–277 V, 50–60 Hz |
| Power Factor | >0.95 | >0.95 | >0.95 | >0.95 |
| CRI | >80; CRI >90 optional | >80; CRI >90 optional | >80; CRI >90 optional | >80; CRI >90 optional |
| CCT | 2700 K / 3000 K / 4000 K / 5000 K / 6000 K | 2700 K / 3000 K / 4000 K / 5000 K / 6000 K | 2700 K / 3000 K / 4000 K / 5000 K / 6000 K | 2700 K / 3000 K / 4000 K / 5000 K / 6000 K |
| Beam Angle | 120° | 120° | 120° | 120° |
| LED Type | SMD 2835 | SMD 2835 | SMD 2835 | SMD 2835 |
| Driver | IC Constant Current Driver | TRIDONIC | TRIDONIC | TRIDONIC |
| Operating Temperature | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C |
| IP Rating | IP67 | IP67 | IP67 | IP69K |
| IK Rating | IK10 | IK10 | IK10 | IK07 |
| Housing Material | Transparent / Opal / Half-Opal PC Housing | Transparent / Opal / Half-Opal PC Housing | Transparent / Opal / Half-Opal PC Housing | Borosilicate Glass Housing |
| End Caps & Brackets | SS304L / SS316L end caps and mounting brackets | SS304L / SS316L end caps and mounting brackets | SS304L / SS316L end caps and mounting brackets | SS304L / SS316L end caps and mounting brackets |
| Installation | Suspended / Surface Mounted / Linkable | Suspended / Surface Mounted / Linkable | Suspended / Surface Mounted / Linkable | Suspended / Surface Mounted / Linkable |
| Available Options | Microwave sensor / 3-hour emergency / dimmable / CCT switchable | Microwave sensor / 3-hour emergency / dimmable / CCT switchable | Microwave sensor / 3-hour emergency / dimmable / CCT switchable | Microwave sensor / 3-hour emergency / dimmable / CCT switchable |
| Product Details | View Ø45 mm Details → | View Ø70 mm Details → | View Ø100 mm Details → | View Ø75 mm Glass Details → |
Values shown are platform-level references. Final performance, certification, driver, control option, and installation configuration must be confirmed using the relevant product datasheet and technical documentation.
Need integrated safety signage, wayfinding graphics, or custom labels? View Custom Safety Signage Tubular Light →
Why MANI Industrial Tubular Lights
Built to Withstand Harsh Industrial Environments
Our industrial tri-proof tubular lighting systems are engineered for water, dust, vibration, chemical exposure, high-pressure washdown, and continuous 24/7 operation.
Engineered for harsh washdown and steam cleaning. Complete defense against dust, high-pressure water jets, and submersion.
Heavy-duty polycarbonate and industrial glass options withstand heavy mechanical impacts, vibration, and severe shock.
High flame-retardant materials compliant with rigorous fire safety standards, making them suitable for tunnels, public hubs, and high-risk facilities.
Bayer PC for max impact resistance, PMMA for high UV stability & optical clarity, Borosilicate Glass for extreme chemical exposure and zero yellowing.
Precision-fitted end caps, protected cable entries, and multi-ring gaskets prevent moisture or chemical vapor ingress over long lifetimes.
Premium LEDs and customized optical diffusers deliver maximum lumen output with reduced energy consumption and operational cost.
Advanced thermal management and industrial-grade drivers minimize maintenance cycles, replacement frequency, and system downtime.
Supports surface mounting, stainless steel suspension, through-wiring, and continuous-run linear trunking to slash wiring labor.
Tailor diameters (Ø45-100mm), length, wattage, CCT/CRI, optics, DALI/0-10V dimming, emergency backup, and custom labeling.
Industrial Tubular Light Selection Guide
Compare protection level, housing material, optical distribution, wiring, and control options before selecting a MANI industrial tubular luminaire.

Selecting the Required Protection Level
Select the protection rating according to dust exposure, cleaning procedure, liquid exposure, mechanical risk, and the applicable project standard.
- IP65: Suitable for selected industrial applications exposed to dust and water jets. Confirm the relevant model's test documentation before specification.
- IP67: Suitable for selected dust-tight configurations requiring protection against temporary immersion. Confirm the exact enclosure, cable entry, connector, and installation configuration.
- IP69K: Intended for selected high-pressure, high-temperature washdown applications, such as food processing, car-wash, and hygiene-critical areas. Confirm the applicable test report for the selected model.
- Impact resistance: Up to IK10 is available on selected configurations. Select the required impact rating according to the risk of contact, vibration, or accidental impact.
Selecting Housing Material for the Installation Environment
Housing material should be selected according to impact risk, UV exposure, cleaning process, chemical exposure, temperature, and required optical appearance.
Polycarbonate (PC)
Typical strengths: High impact resistance and non-shattering performance in applicable configurations.
Typical applications: Workshops, warehouses, logistics areas, parking garages, and vibration-prone installations.
PMMA (Acrylic)
Typical strengths: Optical clarity and UV stability for applicable indoor and outdoor configurations.
Typical applications: Agriculture, livestock facilities, outdoor service areas, and applications where long-term optical appearance is important.
Borosilicate Glass
Typical strengths: A non-porous surface and suitability for selected washdown and chemical-exposure applications.
Typical applications: Food processing, car washes, chemical-processing areas, and hygiene-critical environments.
Important: Validate material compatibility against the actual cleaning agent, concentration, temperature, exposure cycle, and product configuration.
Balancing Optical Performance and Visual Comfort
Select the housing and optical configuration according to mounting height, required illuminance, task visibility, glare limits, and energy target.
- Opal or diffused housing: Designed to create a smoother distribution and reduce harsh shadows in applicable low- to medium-mounting-height installations.
- Clear housing: May be selected where maximum delivered light output is the project priority.
- Glare and efficacy: UGR, luminous flux, and system efficacy depend on the selected model, length, LED package, driver, optic, and installation geometry. Refer to the relevant product datasheet and photometric file.
- Lumen maintenance: Lifetime and lumen-maintenance values must be confirmed for the exact LED and driver configuration being specified.
Planning Continuous-Run Wiring and Installation
Continuous-run systems should be designed around installation method, conductor size, electrical load, protection level, voltage drop, and maintenance access.
- Selected configurations support internal through-wiring for continuous linear runs.
- Connector and end-cap options depend on the selected protection rating and product configuration.
- Surface-mounting brackets and suspension kits are available for selected models.
- Maximum run length must be confirmed through load and voltage-drop calculations for the specific project.

Selecting Controls and Emergency Options
Choose control and emergency functions according to the project electrical design, local regulations, operating schedule, and building-management-system requirements.
- DALI, 0–10V, and TRIAC dimming are available for selected configurations.
- Microwave motion sensors and daylight-harvesting functions are available for selected configurations.
- Emergency backup options are available for selected configurations; confirm the required duration, battery type, self-test function, and applicable standard.
- Custom UV-printed safety graphics, wayfinding markings, product labels, and project branding are available upon evaluation.
Preparing Engineering Documentation for Approval
MANI can provide product-specific documentation to support design, tender, approval, and installation workflows.
- IES and LDT photometric files for applicable models and optical configurations.
- Technical drawings, installation instructions, and selected 3D CAD or BIM files.
- Applicable test reports and compliance documentation for protection, impact resistance, glow-wire performance, and market requirements.
- Model-specific wiring diagrams, product schedules, and configuration support for project approval.
Documentation, test reports, and certificates must be matched to the exact model, electrical configuration, and destination-market requirement.
Applications & Engineering Project Support
Our industrial tri-proof tubular luminaires are engineered for environments where lighting reliability directly affects operational safety, regulatory compliance, and maintenance budgets.

Chemical & Corrosion-Prone Facilities
Corrosion-proof end caps and chemical-resistant glass resisting acidic or caustic atmospheres.

Food Processing & Washdown Areas
IP69K borosilicate glass luminaires built for daily high-pressure chemical and steam cleaning.

Poultry & Agricultural Facilities
Ammonia-resistant PMMA housing with dimming controls optimized for livestock growth cycles.

Car Washes & High-Humidity Zones
Triple-sealed water protection resisting continuous moisture, foam detergents, and humidity.

Parking Garages & Service Corridors
IK10 impact-resistant construction with motion sensors to maximize energy savings.

Metro Stations, Tunnels & Transit
960°C glow-wire fire-retardant platforms compliant with strict public infrastructure safety codes.

Workshops & Manufacturing Plants
Low-glare optical diffusers reducing visual fatigue for technical precision assembly lines.

Warehouses & Logistics Centers
High-uniformity, vibration-proof linear illumination for high-bay aisles and loading docks.
Designed Around Your Project
We support project teams, contractors, lighting designers, distributors, and OEM partners from initial model selection through engineering documentation to final site delivery.
Need Engineering Support?
Send us your floor plans, lux requirements, or environment specs for a tailored proposal.
Discuss Your Project →Quality, Compliance & Warranty
Documentation You Can Use with Confidence
Our industrial tubular lighting systems are developed to support rigorous international project requirements and engineering submittals. Documentation and approvals depend on the selected model and target market.
- IEC 60598 luminaire compliance documentation
- IP67 / IP69K ingress-protection test reports
- IK10 mechanical impact-resistance reports
- 960°C Glow Wire Test resistance reports
- LED Lifetime Data: LM80 / TM-21 reports where applicable
- CE / RoHS compliance documentation
- Utility Model & Design Patents
Minimum 5-Year Warranty Across All Models
Every industrial tubular luminaire in our lineup comes with a minimum 5-year warranty. Please confirm specific project requirements with our technical team prior to order confirmation.

Third-party lab test reports, IP69K/IK10 certificates, utility models, and design patents.
Built with Industry-Proven Components
Depending on project specifications, performance requirements and availability, MANI can integrate selected LEDs, drivers and materials from established industry brands.

Brand names and trademarks are the property of their respective owners. Displayed brands represent components or materials used in selected MANI products and do not imply endorsement, official partnership or use in every product configuration.
Frequently Asked Questions
Find quick answers about model selection, installation, technical documentation, and custom project support.
Q1 What is the difference between IP67 and IP69K for industrial tubular lights?
IP67 is used for selected dust-tight luminaires that require protection against temporary immersion. IP69K is used for selected configurations intended for high-pressure, high-temperature washdown environments.
Select the required rating according to the cleaning procedure, dust exposure, liquid exposure, installation method, and applicable project standard. Always confirm the relevant test report for the exact model, cable entry, connector, and installation configuration.
Q2 When should I specify Borosilicate Glass housing over Polycarbonate (PC)?
Polycarbonate (PC) is commonly selected for applicable configurations requiring high impact resistance, such as logistics centres, parking garages, workshops, and machinery areas.
Borosilicate Glass may be selected for applicable washdown, food-processing, and chemical-exposure environments. Material suitability must be validated against the specific cleaning agent, concentration, temperature, exposure cycle, and selected product configuration.
Q3 How do continuous-run through-wiring setups work?
Selected MANI tubular-light configurations support internal through-wiring for continuous linear runs. Available conductor sizes, terminal blocks, quick-connectors, and end-cap options depend on the selected model and protection requirement.
A correctly designed continuous-run system can help reduce cable runs, junction-box requirements, and installation time. Confirm the load, conductor size, connector rating, maximum run length, and voltage-drop calculation for the specific project before installation.
Q4 Can you provide IES/LDT files for DIALux lighting calculations?
Yes. For applicable product models and optical configurations, MANI can provide IES/LDT photometric files, technical drawings, installation information, and selected 3D CAD or BIM files.
Documentation should be requested for the exact model, length, optic, driver, control option, and project requirement. Our team can also support lighting-layout and DIALux evaluation for qualified projects.
Q5 Can you provide OEM and custom solutions?
Yes. Depending on the product platform and project requirement, MANI can evaluate custom diameters, lengths, wattage, CCT, CRI, optics, mounting hardware, cable connectors, laser labelling, safety graphics, branding, and export packaging.
Final availability, technical performance, minimum order quantity, documentation, and lead time must be confirmed for the selected configuration.
Q6 What information should I provide for a rapid quotation?
To receive an accurate model recommendation and quotation, please provide:
- Target application and installation environment, such as food washdown, warehouse, parking garage, or high-temperature area.
- Preferred diameter and length, or target lux level, mounting height, and installation layout.
- Required input voltage, protection rating, control option, and emergency-lighting requirement.
- Estimated quantity, destination country, target delivery date, and required project documentation.
Have a Specific Project Requirement?
Send us your project brief, drawings, target lux level, environment details, and required documentation. Our technical sales team will recommend a suitable configuration.
Tell Us What Your Business Needs
Whether you need standard bulk orders, private-label OEM/ODM manufacturing, quick-ship stock, or full custom project engineering—MANI delivers reliable industrial lighting tailored to your supply chain.
- ✓ Wholesale & Distribution: High-margin standard products ready for local stock.
- ✓ OEM / ODM / Private Label: Custom specifications, branding, and packaging.
- ✓ Project & Technical Support: Complete IES/CAD files, Dialux studies, and testing.